2010-02-08: CANape 8.0 SP3

Download

With Service Pack 3, the following changes become effective (SP1 and SP2 are contained):

Extended measurement data acquisition:

  • Issue fixed which occurred during replay of CAN messages if the BLF file contains an Application Text object.

Communication protocol:

  • Fixed A2L issue which affected import of DAQ lists.
  • CCP: Completed support of offline datalogger configuration.
  • Improved time synchronization of FlexRay signals from BusDoctorII.
  • Support of SAE J2602 protocol (LIN variant).

Offline analysis of measurement files:

  • Issue fixed which occurred during calculation of the sample reduction.
  • Issue fixed if multiple displays of the same file signal are deleted from a display window.
  • Issue fixed if a ZIP file is selected in the project selection dialog during startup of the application.
  • Issue fixed concerning display of raw values (decimal) from a file signal with rational conversion rule.
  • Logging file import converter supports LIN messages from XLG and XLX files using format V2.

Database:

  • Map file entry search dialog displays all array entries from multiple map files even if address extension is added to the names.
  • Issue fixed that may result into wrong address of bit slice characteristics if the base datatype is WORD or DWORD and an alignment of 2 or greater is defined.
  • Project option added to disable the address alignment of scalar characteristics (Compatibility mode for CANape 6.x)
  • Show warning messages after loading A2L files or updating of addresses in case of an alignment mismatch of characteristics.
  • Issue fixed in the ASAP2 Editor if a database contains a variable with verbal conversion rule and physical unit and this database is saved as version 1.5
  • MAP file format of Fujitsu Softune V60L06 compiler is supported.
  • Show warning messages during saving of an A2L file if identifiers are changed to make them specification conform.
  • Support of A2L identifiers beginning with digits. Such identifiers are not compliant to the "ASAM MCD 2MC / ASAP2" specification. Due to this, such identifiers will be adjusted during a write operation (an underscore is added as prefix).

Calibration data management (Parameter sets & CDM Studio):

  • Improved ASAP2/Simulink object export to support accurate import into MATLAB.
  • Calibration objects will be reinitialized if a change of the current variant is detected during a connect.
  • Undo/Redo supports the "delete parameter" action in order to prevent the creation of corrupt parameter set files.
  • Improved the calibration history such that empty calibration history files are handled correctly.
  • Correct creation of label lists containing variant information in the CDM-Studio preprocess dialog.
  • Improved the generation of the parameter set that represents the current device in the CDM-Studio.
  • Improved the performance of the "parameter explorer", e.g. speed-up of navigation.
  • Added a new option to the "m"-file writer in order to improve the handling of parameters which refer to a verbal conversion table, so that it is possible to write the numerical value of such parameters even if the representation mode is set to physical.
  • Recognize modification if a parameter is deleted from the parameter set in CDM-Studio.
  • Issue fixed that occured when multiple MAP/CURVE parameters were selected in the CDM-Studio and the numerical detail window was visible.

 

[more about CANape...]